Liebert® NXC UPS 10kVA – 60kVA
Liebert Vertiv NXC Features
- 0.9 output power factor
- Double conversion efficiency up to 95%
- Eco mode efficiency up to 98%
- Input current total harmonic distortion correction (THDi) < 4%
- Battery charger up to 6 kW/12 A
- Three or single phase configurable output (up to 20 kVA)
- Integrated manual bypass
- Integrated input and output breakers/switches
- Integrated parallel load bus and synchronization port (LBS)
Liebert® GXT MT+ 6-20KVA
Features
- IGBT Based Rectifier
- True Online Double Conversion with DSP Control Technology for High Performance and Reliability.
- New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting.
- Double Conversion Efficiency upto 90%.
- Active Input Power Factor Correction 0.99.
- 0.8 Output Power Factor.
- Wide Input Voltage window (110 – 280 Vac) for Indian Environmental Condition and for Optimized Battery Performance.
- Configurable Output Voltage (200/208/220/230/240 Vac.)
- Generator Compatible with Wide Input Frequency Range (40 Hz-70 Hz).
- 4 Stage Extendable Charging Design for optimized Battery Performance.
- Adjustable Battery Charging Current 1/2/4/6 Amps according to Battery Capacity and Rating.
- 50/60 Hz Automatic Frequency Converter Mode.
- Intelligent Monitoring with Standard RS232/USB Port Plus Slot Available for RS485/Dry Contact/SNMP Card.
- Inbuilt OVCD.
Liebert® ITA2TM UPS 5-20kVA
Product Specification
Model No. | 6, 10, 20, 30 and 40 KVA |
Product Description
A most compact UPS developed for harshest power conditions. Liebert ITA provides high density, true double-conversion on-line power protection for servers, voice/data networks, and light industrial applications. Capable of delivering loads from 6kVA to 40kVA in a rack/tower convertible form, Liebert ITA is available from 2U to 4U. Liebert ITA series provides customers with a reliable source of uninterruptible power even in demanding power environments, including a very wide input voltage window, extremely tight output voltage regulation, frequency regulation, internal bypass, and input power factor correction. It is used for small and medium-sized data/communication equipment room, network room, business operating room, control room, office space, precision control room & process control room. It’s features are it is IGBT based rectifier,advanced DSP based technology,0.9 Output PF double conversion efficiency up to 95%,ECO mode efficiency up to 98.5%,input PF up to 0.99 ,input Thdi <5%,high capacity battery charger,dynamic design: Rack /Tower convertible,ITA 5-20kVA scalable up to 4 units in N 1 configuration,Integrated parallel load bus and synchronization port (LBS)& easy site installation.